- 15 (or 30) second egress delay
- 1 or 2 second nuisance delay
- Built-in function keypad provides alarm and lock reset, 1 to 30 second bypass, sustained bypass, and additional keyswitch
- Control inputs include 1 to 30 second request to exit and access bypass with anti-tailgate and alarm rest
- Field selectable trigger modes from exit device (N/O or N/C)
- Field selectable automatic or manual power up after emergency release or power loss
Built-in Annunciation:
- Armed mode
- Nuisance mode
- Irreversible egress mode
- Release mode
- Digital countdown display
- Field selectable vice notification or tone
- Field selectable male or female voice
Code Compliance:
- IFC International
- IBC International Building Code
- NFPA 101 Life Safety Code
- NFPA 1 Uniform Fire Code
- California Building Code
Electrical Specs:
- Voltage Input:
• Single 430 mA @ 24VDC
• Tandem 680 mA @ 24VDC
- Reset input: N/O, Dry input
- Rex input: N/O, Dry input
- Trigger: N/C, Dry input
- DPS input: N/O, Dry input
Monitoring Outputs:
- Secure / Insecure status
- Egress initiation status
- Released / Bypass status
- Alarm relay - 1 amp @ 30VDC SPDT, Dry
- Door security relay - 1 amp @30VDC SPDT, Dry