- Archer, August, William or Withnell lever with escutcheon (3902, 1-5/8" cylinder with standard cam sold separately)
- Mortise cylinder (1-3/8") with cylinder collar (11/16") x optional pull
- Mortise trim (45MB, 45MC, 45MD, 45MN) does not match center line of other 4500 Series trim ( 45BE, 45CE, 45DT, 45NL)
- Standard end cap (zinc)
- OPTIONAL Flush end cap (zinc)
Door Width:
- 36'' (914 mm) field sizeable to 30'' (762 mm) panic-rated door and 28" (711 mm) fire-rated door
- 48'' (1219 mm) field sizeable to 36'' (914 mm) panic- or fire-rated door
- Reference electrified exit device for door width specifications
Door Thickness:
- 1-3/4" (44 mm) - Standard
Stile Width:
- 4-1/2" (114 mm)
- All stile widths are measured from the door edge
Fasteners:
- Wood and machine screws
- Thru-bolts
Latchbolt:
- 3/4" (19 mm) throw with anti-friction tongue, all stainless steel with auxiliary deadlocking latch
Push Bar:
- OPTIONAL Photoluminescent push bar cover available
Strikes:
- 4-7/8" (124 mm) ASA strike-standard
- Stainless steel with plated rollers included standard with panic devices
Finishes:
- US3, US4, US10, US10B, US26, US26D, US32D
Dogging:
- Hex key dogging standard on panic rated devices
- Cylinder dogging available on panic rated devices, specify "CD" ( 3902 mortise cylinder with standard cam sold separately)
Projection:
- 3" (76 mm) in undogged position
- 2-5/8" (67 mm) in dogged position
Notes:
- Recommended to be used on appropriately reinforced doors